Soil moisture sampling sleeve.
An open-window 100 mm insertion-depth guide for a 6 mm cylindrical probe, with an adjustable stop collar and cap for the empty guide.

INTERACTIVE 3D PREVIEW
See it from every angle.
Loading 3D preview…
Drag to rotate · Scroll to zoomPLANT WORKSHOP / PROTOTYPE
Make and assemble.
All dimensions are in millimeters. These designs have passed digital mesh checks but have not been physically printed or tested. Check fit, water resistance, and load capacity for your setup.
Parts to print
- guide × 124 x 24 x 104 mm overall. Print flange down, then invert for installation. Shaft insertion depth is 100 mm.
- stop collar × 124 x 20 x 10 mm. Print flat with nut-loading slot upward. 6.6 mm center bore.
- cap × 130 x 30 x 7.4 mm. Print closed face down, then invert to cover the empty guide.
Additional components
- 1 compatible 6 mm cylindrical soil probe with enough straight shaft to reach the desired depth; not supplied.
- 1 M3 hex nut, nominal 5.5 mm across flats x 2.4 mm thick.
- 1 M3 x 12 mm blunt-tip screw or thumb screw; a nylon tip avoids marking a coated probe.
Assembly
- Remove rough edges and verify the 6 mm probe moves freely through the nominal 6.8 mm guide bore.
- Push the guide shaft into loose soil until the underside of its 24 mm flange rests on the surface. The open-ended shaft is 100 mm below this flange. Avoid forcing it against stones.
- Allow soil to fill the guide windows so the sensing section can contact representative soil; do not leave an empty air-filled sleeve around a contact sensor.
- Drop the M3 nut into the stop-collar top slot. Insert the M3 screw from the side and engage the nut.
- Slide the collar onto the probe. Set your intended sensor depth, then tighten only enough to hold the collar. The collar seats on top of the guide flange to repeat that depth.
- Remove the probe and collar together when taking a reading elsewhere. Fit the separate cap only when the guide is empty.
Print notes
- Prototype starting point: PETG, 0.4 mm nozzle, 0.20 mm layers, 4 walls, 5 bottom/top layers, 20% infill.
- The guide is exported flange-down for bed adhesion; its tapered open end prints upward. No supports are intended.
- The M3 nut pocket is 2.8 mm thick by 5.8 mm wide and loads vertically; clean it before inserting the nut.
- Bore clearance and collar screw travel require a dry fit on your actual probe before use.
Limitations
- PROTOTYPE / NOT PHYSICALLY TESTED. This is a repeatable placement guide, not a calibrated moisture instrument.
- The default fits a cylindrical 6 mm probe only, not flat capacitive PCB probes or multi-prong forks.
- The sleeve can alter local soil contact and drainage. Compare readings with direct soil measurements for your instrument.
- Do not clamp a delicate sensing coating or force the guide into compacted or stony soil.